Introduction
This year, GLP-1 analogs are set to overtake PD-1 inhibitors as the best-selling class of drugs. By 2030, hundreds of millions of patients worldwide may rely on GLP-1 drugs to manage their health, some for a period of years, others perhaps indefinitely. The initially unforeseen clinical success of GLP-1 drugs and their rate of adoption has already led to a number of challenges for the industry, from the ability to manufacture the drug to bottlenecks due to fill-finish capacity to payers tackling reimbursement. Assuming these are addressed in coming years, there are still significant questions about how we can address the environmental sustainability challenges created by this new market and the vast patient population.
In the short term, scaling the production of proven, existing single-use autoinjector (AI) and insulin-style or cartridge-based injector pen technologies are likely the best option to meet the rate of demand. Cartridge-based injector pens offer one route to reduce the environmental impact as compared to single-use devices, as they typically deliver up to 4 doses with only the needle hub discarded after each dose. But these advantages are offset by the usability challenges compared to single-use AIs, including dose setting, an exposed needle, and an increased number of steps to dispose and replace it.
Longer-term, can traditional pens designed to deliver insulin work for the needs of a patient on GLP-1? Is it acceptable to follow the same single-use disposable path for such a large market that is set to grow each year to 2030? Will this approach be acceptable to patients when more convenient and sustainable solutions could be available?i
For some years now, the industry has been weighing up the potential of a reusable, durable AIs. This would take the form of a hand-held device that reuses the power system each time but delivers the drug from a single-use disposable as a route to lower environmental impact per dose. This disposable would contain a pre-filled syringe (PFS) that is in drug and patient contact. Whilst there has been some progress in this realm, the requirements of GLP-1 drugs are also different from those for which existing reusable AIs were developed.
This article explores this premise further and proposes that simple mechanically driven reloadable AIs may balance environmental sustainability and economic opportunities to create the best of both worlds.
The growth curve ahead
The metabolic diseases of diabetes and now increasingly weight management, collectively known as diaobesity, are currently driving unprecedented demand for GLP-1 drugs. According to one estimate, the number of patients to be treated in the United States is on track to reach 30 million by 2030.ii Whilst some of the demand will be met with orally taken treatments,iii the increase in the U.S. alone could equate to 1 billion injections per year.
While welcomed by patients, the rapid growth of GLP-1 drugs over the next decade is bringing into focus the need for environmentally sustainable drug delivery solutions for self-injection. An additional 1 billion typical single-use AIs discarded after use could equate to 35,000 tonnes or 50,000 cubic meters of waste – and enough devices to circle the globe 3.5 times!
Reducing environmental impact
These staggering numbers clearly show environmental sustainability should be considered from the outset of future drug product launches in this category. To justify the investment into a new drug delivery platform often requires an order of magnitude improvement over incumbent devices and there are only limited ways this can be achieved with the design of current products and processes.
An obvious method to enhance sustainability would be through minimising the amount of material used during manufacture. While some opportunities here may exist, many legacy products have been optimised for part count, material usage, manufacturing method and assembly, so the benefits from this approach alone are limited. An alternative would be to develop an AI made with more sustainable materials from the outset, such as the Eco-Inject® platform. The number of bio-based and biodegradable polymers is increasing steadily, making it possible to meet mechanical performance requirements. However, these new materials still command a premium over conventional medical grades, which will impact cost per dose until they are available and adopted at scale.
Full circularity is a more radical approach focused on maximising the takeback and recycling of a device through material choices and design for disassembly at end of life. The infrastructure, logistics and regulation are taking shape, albeit at different rates in different territories, and takeback schemes are being trialled in various industries. HeathBeacon® is one of the leaders in this field and tackling the complexities required for collecting devices with sharps that have been in contact with both the drug and the patient. Circularity via recycling or takeback is being piloted but as well as being physically possible it must also be economically viable at scale if the benefits are to be relished.
A reloadable and reusable autoinjector?
One potential option to tackle this challenge is to develop an AI intended to be reloaded and reused. Reusing the drive system and several components across multiple deliveries is a practical way to significantly lower environmental impact per dose. The user is still required to load the device between uses but - unlike traditional cartridge-based pens - the needle would not be seen by a patient prior to an injection and shielded post-injection, features that both reduce anxiety and increase safety during self-injection.
To date, existing reusable platforms in this area have typically been designed around powerful electromechanical drive systems to drive (often viscous) biological drugs. This results in costly battery-powered devices that have then sought to include additional functionality and connected features to justify the increased costs. In the context of GLP-1, rather than repurposing this approach, the needs of the new patient population and scale of the market should be taken into account when developing the correct delivery solution.
GLP-1s tend to have favourable properties for injection such as low viscosity and relatively small dose volumes that can be delivered from a PFS via a spring-powered device. For a drug regime like that of many GLP-1s, where patients administer a dose weekly, it is easy to see how simple reloadable AIs could offer a significant improvement in environmental sustainability performance over single-use devices.
To maximise the environmental benefit of this approach, as much of the complex high value components (actuator, needle safety, ergonomic handle, etc.) would be integrated into the reusable section of the device. The disposable would appear as a simple cassette that would house the PFS and enable the user to easily reload the AI.
Unique design challenges to overcome
A mechanical reloadable design brings clear environmental sustainability benefits but conversely creates unique design challenges. Some are technical, such as part durability, human error during user loading versus preloaded, ensuring a lockout at end of life of the device, etc. Others are more nuanced and require significant design innovation to develop a device that meets the requirements for sustainability whilst at the same time satisfying the user and being compatible with existing manufacturing methods and fill-finish equipment.
Primary Containment
When it comes to the primary containment, dedicated innovation is best avoided. Seeking a custom packaging solution introduces technical, logistical, and commercial challenges to both the manufacturing and fill-finish operations. Instead, all efforts should be put to integrating an off-the-shelf PFS solution that will have been optimised, tested and already proven scalable into the reloadable AI design.
User Acceptance and Adherence
To gain adoption in a mass market dominated by single-use devices, a reloadable AI should offer a familiar format and design affordances, identical or similar user steps for injection, and intuitive reloading steps. In practice, it should offer familiar haptic cues so that users can recall functional steps. As far as possible, these steps should follow current accepted practice; any new steps should draw on recognisable and familiar affordances associated with reloading or refreshing a device. Examples can be drawn from our everyday lives and the many different coffee machines and coffee pods we have become accustomed to prepare our daily dose of caffeine with minimal training.
Device Simplicity
It may at first appear that a reloadable AI will increase complexity for the user. Typically, additional steps are required to swap over PFS in a reusable device. To reduce the number of steps the functions required could be designed into a novel cassette design. Going a step further, an ideal solution would make reloading the AI feel simpler and more worthwhile to the user than unpacking and throwing away a whole device after each use.
Regulatory
A device design with similar user steps and interaction cues to existing marketed devices would be preferred. There is precedent for FDA-approved reusable AIs intended for different therapeutic indications (e.g., Skytrofa Auto-Injector; Rebiject II® Auto-Injector; Enbrel Autotouch®). Care should be taken to not deviate significantly from familiar device interactions or introduce handling steps not supported by extensive usability studies.
Commercial benefits: cost per dose and scalability
Simple reloadable and reusable AIs are also a pragmatic solution that balances environmental sustainability and economics in a way that favours adoption and scalability. Fundamentally, a smaller number of reloadable devices of comparable complexity to a single-use device will need to be manufactured and assembled to supply the same number of doses – or to keep up with the growing demand of the GLP-1 market.
In a field saturated by single-use devices, reloadable AIs also give pharmaceutical companies an opportunity to offer product differentiation while aligning with growing demand for sustainability from users and legislators.
Conclusion
In the short to medium term, simple reloadable AIs are a credible option to align environmental sustainability with commercial drivers, in particular the need to scale. To realize this opportunity, the stakeholders need to collaborate to resolve several interrelated design and manufacturing challenges. Many of these start with the needs of the end user, including anticipating the minimum device features expected, ensuring the injection experience does not deviate significantly, and integrating the existing PFS solutions into the cassette design so it is intuitive and reliable to reload.
The size of the GLP-1 market means that there are vast revenues to be generated for a number of pharma companies, albeit with a high degree of competition and difficulty around differentiation. It would be hoped that the societal benefit of these new drugs is to be combined with similar innovations in delivery that lead to scalable, reusable AI solutions that ensure that the millions of patients, and the environments they live in, have a healthy and more sustainable outlook to 2030 and beyond.
This article was originally published on ONdrugDelivery
About TTP's Drug Delivery consulting team
From blank sheet to clinical reality, TTP's Drug Delivery design and development team creates groundbreaking solutions to solve the toughest drug delivery challenges. With deep engineering, human factors, and scientific expertise, we guide you through every stage of drug delivery device development - from early exploration to manufacturing and final launch. Backed by an extensive track record we expertly navigate constraints to develop robust, efficient, scalable devices - enabling the delivery of transformative therapies and enhanced patient experiences. Find out how we can help you with your drug delivery solutions needs. Get in touch today.
References
- Zhou A, Trujillo J, “Comparison of Usability, Accuracy, Preference, and Satisfaction Among Three Once-Weekly GLP-1 Receptor Agonist Pen Devices”. Diabetes Spectr, 2018, Vol 31(4), pp 359–366.
- “The increase in appetite for obesity drugs”. Research Analysis, J.P. Morgan, Nov 29, 2023.
- Boye K et al, “Patients’ preferences for once‐daily oral versus once‐weekly injectable diabetes medications: The REVISE study”. Diabetes Obes Metab, 2021, Vol 23(2), pp 508–519.